Many models contain a variable that is much faster than the others. If it relaxes to a stable value, it can be replaced by that value, as a function of the slow variables, and the model loses a dimension. This is the quasi-steady state (QSS) approximation, and it is the singular limit of The Singular Limit again, now with two variables. The recipe is to scale until a small multiplies the fast derivative, check that the fast variable relaxes, reduce, and then ask what the reduction gets wrong: usually only the first moments, and sometimes that is exactly what matters. This page gives the method; the two pages after it apply it to an enzyme and to the drug of Drug and Bacteria in the Plane.
Two variables, two clocks¶
In Nondimensionalization the equation of motion of a cell was scaled to ((11)), with the ratio of the cell’s inertial time to the time of the question. In The Singular Limit, setting replaced the differential equation by the algebraic one : the velocity followed the force instantaneously, and the initial velocity was lost in a layer of width . There the slow quantity, the force, was prescribed. Now let it have an equation of its own.
Definition 1 (Fast-slow system)
A fast-slow system is
with the slow variable and the fast variable. Time is measured on the slow scale, and is the ratio of the fast time scale to the slow one.
is never given; it is found by scaling, as in Nondimensionalization. Choose units for each variable and for time so that and are of order one; is whatever dimensionless group is left in front of a derivative. If no small group appears there, there is no separation of time scales and the QSS approximation has no justification. Setting gives the same objects as in The Singular Limit.
Definition 2 (Critical manifold, reduced problem, layer problem)
The critical manifold is the set where the fast equation is at rest, . Where it can be solved as , the fast variable is slaved to the slow one.
The reduced problem (the outer problem) is the slow equation on the critical manifold,
The layer problem (the inner problem) is the fast equation on the fast time , with :
The reduced problem is one dimension smaller than the full one and cannot take an initial value for ; that value is lost in the layer, as the initial velocity was. The layer problem says where goes while has not had time to move, and for the reduction to make sense must go to the critical manifold. The layer problem is a flow on a line with a steady state at , so by the slope test (Proposition 1) this holds when
A critical manifold with this property is attracting. Where the slope is positive the manifold repels, and the reduction describes nothing that can be observed.
| singular limit of a cell | fast-slow system | |
|---|---|---|
| equation | , | |
| slow quantity | the force , prescribed | , with its own equation |
| outer solution | (Definition 2) | and the reduced problem |
| inner solution | on , force frozen (Definition 2) | on , frozen |
| attracting | (4) | |
| error | at most (Theorem 1) | (Tikhonov, below) |
Theorem 1 (Tikhonov)
We state this without proof Tikhonov, 1952. It is the nonlinear version of Theorem 1, as noted in Remark 3: the slow variable is right from the start, the fast variable after the layer. For the drug model, Proposition 4 of Drug and Bacteria in the Plane proves the part that matters by hand.
Tikhonov’s theorem holds on a fixed finite interval . It does not say which steady state a solution reaches as . Near a threshold a solution can hesitate for a long time before it decides, and that long-time question needs a separate argument. The drug example of The Drug Is Fast is such a case.
Scale. Find units in which a small multiplies one derivative. Write in the original parameters and estimate it.
Slave. Solve for , the critical manifold.
Check. Verify on it. Without this the reduction is wrong, not just inaccurate.
Reduce. Substitute into the slow equation.
Ask what was lost. The initial value of , and corrections. Decide whether the question at hand can see them.
Two examples¶
Michaelis-Menten Kinetics: an enzyme converts its substrate. The small parameter is the ratio of enzyme to substrate, and the reduction gives the Michaelis-Menten law. Step 5 finds that only the first instant is lost.
The Drug Is Fast: the drug and the bacteria of Drug and Bacteria in the Plane. The small parameter is the growth rate of the cells over the clearance rate of the drug. Here step 5 matters: the steady states are exact, the dynamics are slowed slightly, and the threshold inoculum depends on the initial drug level, which the reduced model cannot express.
In both examples the critical manifold is attracting everywhere, so the recipe works along every solution. When the critical manifold folds back on itself, condition (4) fails at the folds, and the fast variable jumps. That is the situation of Pulses and Oscillations: FitzHugh–Nagumo.
- Tikhonov, A. N. (1952). Systems of differential equations containing small parameters in the derivatives. Matematicheskii Sbornik, 31(73)(3), 575–586.